Please choose a product below for solutions to many common conditions that are often addressed by our Technical Service department.
Click on the product name or the + symbol to expand the product area and see the troubleshooting tips. Click on the product name again to close and see the full product list.
Excess Concentrate Draw
Cause: Metering tip not in place
Solution: Press correct tip firmly into barb on eductor
Cause: Chemical above eductor
Solution: Place concentrate below the eductor
Excess Foaming in Discharge
Cause: Air leak in pick-up tube
Solution: Put a clamp on tube or replace tube if brittle
Failure Of Unit To Turn Off
Cause: Water valve parts dirty or defective
Solution: Clean or replace with valve parts kit
Cause: Magnet does not fully return
Solution: Ensure magnet moves freely
Cause: Push button stuck
Solution: Remove button and clean cabinet/button to remove any dirt lodged in slide recess
No Concentrate Draw
Cause: Clogged foot valve
Solution: Clean or replace
Cause: Metering tip or eductor has scale build-up
Solution: Clean (descale)* or replace
Cause: Low water pressure
Solution: Minimum 20 PSI (with water running) required to operate unit properly
Cause: Discharge tube(s) not in place or flooding ring missing from inner discharge tube
Solution: Push tube firmly onto eductor discharge hose barb; be sure inner discharge tube is installed and has flooding ring
Cause: Concentrate container empty
Solution: Replace with full container
Cause: Inlet hose barb not screwed into eductor tightly
Solution: Tighten, but do not overtighten
Cause: Clogged water inlet strainer
Solution: Disconnect inlet water line and clean strainer
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Discharge
Cause: No water
Solution: Open water supply
Cause: Magnetic valve not functioning
Solution: Install valve parts kit
Cause: Excessive water pressure
Solution: Install regulator if water pressure exceeds 60 PSI (flowing)
Cause: Eductor clogged
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Water Discharge From Air Vents On Eductor
Cause: Restricted discharge hose
Solution: Be sure discharge tube is not immersed, kinked, or elevated. Be sure there is no liquid in the discharge tube when beginning to operate dispenser
Cause: High water pressure
Solution: Install pressure regulator if flowing water pressure exceeds 60 PSI (flowing)
Excess Foaming In Discharge
Cause: Air leak in pick-up tube
Solution: Put clamp on tube or replace tube if brittle
No Concentrate Draw
Cause: Concentrate container empty
Solution: Replace with full container
Dead or No Display
Ensure that controller is connected to pump module via J1 cable
Ensure that power is connected to pump module
Check to see if the pump module circuit breaker is tripped
Load Count Errors
Quite a number of perceived load count errors may occur in the normal day-to-day operations of a laundry. A load is counted (to the current formula number) each time the highest pump number with a nonzero amount runs. In Relay mode a load is counted each time pump 1 is run.
Load Counts High
Check washer trigger signal for count pump running more than once each load.
Load Counts Low
Check washer trigger signals
Check that machine operator may be short cycling the washer
Pumps Don’t Prime
Confirm pump motor harness is connected to PI PCB in pumpstand
Follow pumpstand manual troubleshooting procedures for PI PCB defect
Pumps Don’t Run
When pumps don’t run it is important to differentiate between running on prime and running from a machine trigger. Pumps only run formula amounts from a machine trigger when pumps are calibrated.
When only certain pump positions are defective, check Pump Interface (PI) printed circuit board (PCB) and J1 cable connections.
Only one pump may run at a time in flush mode. Multiple pumps triggered at the same time will run in queue.
No Pumps On Trigger, Prime OK
Are pumps calibrated?
Is a delay time programmed or is pump in cue?
Is there a trigger signal? Confirm by viewing lights on Machine Interface and measuring signal with a volt meter.
Follow pump module manual troubleshooting procedures for MI defect.
Test run pump amounts as described in step 5.4.2 or Program Mode.
Backflow Into Concentrate
Cause: Eductor check valve inoperable
Solution: Clean or replace check valve
Discharge From Backflow Preventer Vent
Cause: Backflow preventer check valve dirty or defective Water hammer condition in supply system (cause of “splitting”) Negative pressure in supply line causing reverse flow
Solution: Clean or replace backflow preventer (Kit #105) Install water hammer shock arresters or water pressure reducing valves
Excess Concentrate Draw
Cause: Metering tip not in place (or wrong metering tip)
Solution: Press correct tip firmly into barb
Leaks At Plastic And Copper Junctions
Cause: Compression nut loose
Solution: Tighten nut 1/2 turn
Leaks At Plastic Tube
Cause: Compression nut loose
Solution: Tighten nut 1/2 turn
Low Or No Water Flow
Cause: Inlet screen clogged
Solution: Clean or replace
Cause: Supply source inadequate
Solution: 4 GPM flow necessary to operate unit; move unit or replumb incoming line
Cause: Scaled eductor or fittings
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Concentrate Draw
Cause: Clogged check valve
Solution: Clean or replace
Cause: Metering tip clogged
Solution: Rinse in hot water or replace: DO NOT REAM CLEAN!
Cause: Eductor clogged
Solution: Clean or replace
Cause: Clogged water inlet
Solution: Clean screen
Cause: Clogged foot strainer
Solution: Clean or replace
Cause: Low water pressure and/or volume
Solution: Replace with full container
Cause: Check valve not screwed into eductor firmly
Solution: Tighten, but DO NOT OVERTIGHTEN!
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Discharge
Cause: No water
Solution: Open water supply
Cause: Excessive water pressure
Solution: Install regulator if water pressure exceeds 85 PSI (flowing)
Cause: Eductor clogged
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Water Flow Won’t Shut Off
Cause: Ball valve defective
Solution: Replace
Weak Foaming Action
Cause: Clogged water inlet strainer
Solution: Clean or replace
Cause: Water pressure too low
Solution: Minimum 25 PSI required
Cause: Water temperature too high
Solution: Use lower temp water source (Concentrate flow decreases above 140 degrees F water)
Weak Spraying Action
Cause: Clogged water inlet strainer
Solution: Clean or replace
Cause: Water pressure too low
Solution: Minimum 25 PSI required
No Concentrate Draw
Cause: Clogged check valve
Solution: Clean or replace
Cause: Metering tip clogged
Solution: Rinse in hot water or replace: DO NOT REAM CLEAN!
Cause: Eductor clogged
Solution: Clean or replace
Cause: Clogged water inlet
Solution: Clean screen
Cause: Clogged foot strainer
Solution: Clean or replace
Cause: Low water pressure and/or volume
Solution: Clean or replace
Cause: Check valve not screwed into eductor firmly
Solution: Tighten, but DO NOT OVERTIGHTEN!
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Weak Foaming Action
Cause: Clogged water inlet strainer
Solution: Clean or replace
Cause: Water pressure too low
Solution: Minimum 25 PSI required
Cause: Water temperature too high
Solution: Use lower temp water source (Concentrate flow decreases above 140 degrees F water)
Excess Concentrate Draw
Cause: Metering tip not in place
Solution: Press correct tip firmly into barb on eductor
Cause: Chemical above eductor
Solution: Place concentrate below the eductor
No Concentrate Draw
Cause: Clogged foot valve
Solution: Clean or replace
Cause: Metering tip or eductor has scale build-up
Solution: Clean (descale)* or replace
Cause: Low water pressure
Solution: Minimum 20 PSI (with water running) required to operate unit properly
Cause: Discharge tube(s) not in place or flooding ring missing from inner discharge tube
Solution: Push tube firmly onto eductor discharge hose barb; be sure inner discharge tube is installed and has flooding ring
Cause: Concentrate container empty
Solution: Replace with full container
Cause: Inlet hose barb not screwed into eductor tightly
Solution: Tighten, but do not overtighten
Cause: Clogged water inlet strainer
Solution: Disconnect inlet water line and clean strainer
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Excess Concentrate Draw
Cause: Metering tip not in place
Solution: Press correct tip firmly into barb on eductor
Cause: Chemical above eductor
Solution: Place concentrate below the eductor
Excess Foaming in Discharge
Cause: Air leak in pick-up tube
Solution: Put a clamp on tube or replace tube if brittle
Failure Of Unit To Turn Off
Cause: Water valve parts dirty or defective
Solution: Clean or replace with valve parts kit
Cause: Magnet does not fully return
Solution: Ensure magnet moves freely
Cause: Push button stuck
Solution: Remove button and clean cabinet/button to remove any dirt lodged in slide recess
No Concentrate Draw
Cause: Clogged foot valve
Solution: Clean or replace
Cause: Metering tip or eductor has scale build-up
Solution: Clean (descale)* or replace
Cause: Low water pressure
Solution: Minimum 20 PSI (with water running) required to operate unit properly
Cause: Discharge tube(s) not in place or flooding ring missing from inner discharge tube
Solution: Push tube firmly onto eductor discharge hose barb; be sure inner discharge tube is installed and has flooding ring
Cause: Concentrate container empty
Solution: Replace with full container
Cause: Inlet hose barb not screwed into eductor tightly
Solution: Tighten, but do not overtighten
Cause: Clogged water inlet strainer
Solution: Disconnect inlet water line and clean strainer
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Discharge
Cause: No water
Solution: Open water supply
Cause: Magnetic valve not functioning
Solution: Install valve parts kit
Cause: Excessive water pressure
Solution: Install regulator if water pressure exceeds 60 PSI (flowing)
Cause: Eductor clogged
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Water Discharge From Air Vents On Eductor
Cause: Restricted discharge hose
Solution: Be sure discharge tube is not immersed, kinked, or elevated. Be sure there is no liquid in the discharge tube when beginning to operate dispenser
Cause: High water pressure
Solution: Install pressure regulator if flowing water pressure exceeds 60 PSI (flowing)
Excess Foaming In Discharge
Cause: Air leak in pick-up tube
Solution: Put clamp on tube or replace tube if brittle
No Concentrate Draw
Cause: Concentrate container empty
Solution: Replace with full container
Excess Concentrate Draw
Cause: Cause: Metering tip not in place
Solution: Press correct tip firmly into barb on eductor
Cause: Chemical above eductor
Solution: Place concentrate below the eductor
Excess Foaming in Discharge
Cause: Air leak in pick-up tube
Solution: Put a clamp on tube or replace tube if brittle
Failure Of Unit To Turn Off
Cause: Water valve parts dirty or defective
Solution: Clean or replace with valve parts kit
Cause: Magnet does not fully return
Solution: Ensure magnet moves freely
Cause: Push button stuck
Solution: Remove button and clean cabinet/button to remove any dirt lodged in slide recess
No Concentrate Draw
Cause: Clogged foot valve
Solution: Clean or replace
Cause: Metering tip or eductor has scale build-up
Solution: Clean (descale)* or replace
Cause: Low water pressure
Solution: Minimum 20 PSI (with water running) required to operate unit properly
Cause: Discharge tube(s) not in place or flooding ring missing from inner discharge tube
Solution: Push tube firmly onto eductor discharge hose barb; be sure inner discharge tube is installed and has flooding ring
Cause: Concentrate container empty
Solution: Replace with full container
Cause: Inlet hose barb not screwed into eductor tightly
Solution: Tighten, but do not overtighten
Cause: Clogged water inlet strainer
Solution: Disconnect inlet water line and clean strainer
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Discharge
Cause: No water
Solution: Open water supply
Cause: Magnetic valve not functioning
Solution: Install valve parts kit
Cause: Excessive water pressure
Solution: Install regulator if water pressure exceeds 60 PSI (flowing)
Cause: Eductor clogged
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Water Discharge From Air Vents On Eductor
Cause: Restricted discharge hose
Solution: Be sure discharge tube is not immersed, kinked, or elevated. Be sure there is no liquid in the discharge tube when beginning to operate dispenser
Cause: High water pressure
Solution: Install pressure regulator if flowing water pressure exceeds 60 PSI (flowing)
Excess Foaming In Discharge
Cause: Air leak in pick-up tube
Solution: Put clamp on tube or replace tube if brittle
No Concentrate Draw
Cause: Concentrate container empty
Solution: Replace with full container
Dead or No Display
Confirm main power connection voltage with a volt meter. Check fuse if optional fuse kit is installed. Substitute transformer followed by the printed circuit board to determine fault.
Excess Detergent Consumption
7.4.1 Probe Mode
Check probe for scaling and measure wash solution via titration kit or by other means. If detergent us at proper concentration, troubleshoot the dish machine for clogged drains, excessive fresh water feedback, etc.
7.4.2 Probe-less Mode
Confirm that initial charge is dispensed only one time per initial fill. if you experience multiple initial charge feeds (Automatic/Conveyor mode only) review initial charge wiring connection. All other modes, adjust initial charge and dose adjustments accordingly.
No Detergent Feed
7.3.1 Probe Mode
Temporarily disconnect probe wire with detergent signal on to force detergent feed.
If detergent feeds, check for probe scaling and check detergent setpoint setting.
If detergent does not feed, substitute pump motor (or solenoid coil) followed by the printed circuit board to determine fault.
7.3.2 Probe-less Mode
Confirm that unit is in a detergent feed condition as determined by rinse/initial charge signal inputs and initial charge/dose adjustments.
If detergent does not feed, substitute pump motor (or solenoid coil) followed by the printed circuit board to determine fault.
No Rinse Feed
Rinse feed is locked out under the following conditions:
Probe-less/Door/Automatic Initial Charge modes – Rinse is locked out after Initial Charge begins until the following rack (rinse signal) occurs.
Probe Mode – detergent signal did not occur within 90 seconds prior to rinse signal (Rinse Saver feature).
If not in one of the above conditions and rinse does not feed, substitute pump motor followed by the printed circuit board to determine fault.
Excess Concentrate Draw
Cause: Metering tip not in place
Solution: Press correct tip firmly into barb on eductor
Cause: Chemical above eductor
Solution: Place concentrate below the eductor
Excess Foaming in Discharge
Cause: Air leak in pick-up tube
Solution: Put a clamp on tube or replace tube if brittle
Failure Of Unit To Turn Off
Cause: Water valve parts dirty or defective
Solution: Clean or replace with valve parts kit
Cause: Magnet does not fully return
Solution: Ensure magnet moves freely
Cause: Push button stuck
Solution: Remove button and clean cabinet/button to remove any dirt lodged in slide recess
No Concentrate Draw
Cause: Clogged foot valve
Solution: Clean or replace
Cause: Metering tip or eductor has scale build-up
Solution: Clean (descale)* or replace
Cause: Low water pressure
Solution: Minimum 20 PSI (with water running) required to operate unit properly
Cause: Discharge tube(s) not in place or flooding ring missing from inner discharge tube
Solution: Push tube firmly onto eductor discharge hose barb; be sure inner discharge tube is installed and has flooding ring
Cause: Concentrate container empty
Solution: Replace with full container
Cause: Inlet hose barb not screwed into eductor tightly
Solution: Tighten, but do not overtighten
Cause: Clogged water inlet strainer
Solution: Disconnect inlet water line and clean strainer
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Discharge
Cause: No water
Solution: Open water supply
Cause: Magnetic valve not functioning
Solution: Install valve parts kit
Cause: Excessive water pressure
Solution: Install regulator if water pressure exceeds 60 PSI (flowing)
Cause: Eductor clogged
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Water Discharge From Air Vents On Eductor
Cause: Restricted discharge hose
Solution: Be sure discharge tube is not immersed, kinked, or elevated. Be sure there is no liquid in the discharge tube when beginning to operate dispenser
Cause: High water pressure
Solution: Install pressure regulator if flowing water pressure exceeds 60 PSI (flowing)
Backflow Into Concentrate
Cause: Eductor check valve inoperable
Solution: Clean or replace check valve
Excess Concentrate Draw
Cause: Metering tip not in place (or wrong metering tip)
Solution: Press correct tip firmly into barb
Low Or No Water Flow
Cause: Inlet screen clogged
Solution: Clean or replace
Cause: Supply source inadequate
Solution: 4 GPM flow necessary to operate unit; move unit or replumb incoming line
Cause: Scaled eductor or fittings
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Concentrate Draw
Cause: Clogged check valve
Solution: Clean or replace
Cause: Metering tip clogged
Solution: Rinse in hot water or replace: DO NOT REAM CLEAN!
Cause: Eductor clogged
Solution: Clean or replace
Cause: Clogged water inlet
Solution: Clean screen
Cause: Clogged foot strainer
Solution: Clean or replace
Cause: Low water pressure and/or volume
Solution: Replace with full container
Cause: Check valve not screwed into eductor firmly
Solution: Tighten, but DO NOT OVERTIGHTEN!
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
No Discharge
Cause: No water
Solution: Open water supply
Cause: Excessive water pressure
Solution: Install regulator if water pressure exceeds 85 PSI (flowing)
Cause: Eductor clogged
Solution: Clean* or replace
* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Water Flow Won’t Shut Off
Cause: Ball valve defective
Solution: Replace